for domestic water Circulation set

System components
All system components
use
The device is designed for domestic water systems with a hygienic storage tank with a stainless steel heat exchanger and a circulation pump. The set includes a mixing valve with temperature adjustment option.
function
The circulation set works by supplying the point of consumption with domestic water via a circulation circuit. The domestic water is mixed with the hot water in the three-way piece at the storage tank outlet and then mixed with cold domestic water through a thermostatic valve set to the set temperature.
assembly
The circulation set must be flushed before installation. The circulation set is connected directly to the hot water from the storage tank. When installing the circulation set, the applicable regulations, standards and guidelines must be observed.
Technical Data
Max. Temp | 90°C |
Max. operating pressure | 10 bar |
Max. differential pressure | 3 bar |
adjustment range | from 35°C to 60°C |
Connection | AG ¾" |
connection - circulation | AG ½" |
Connection | AG 1" |
material | brass and stainless steel |
pressure loss diagram
Pressure loss between hot water and mixed water is measured at 65°C, hot water temperature: 80°C, cold water temperature: 10°C.