Application : WEBER ENERGY generators are compact and reliable devices that provide an independent and self-contained power source. They are ideal in emergency situations and wherever there is no electricity available. Products with 4-stroke, 1-cylinder combustion engine with voltage stabilization system
* Zdjęcie produktu przedstawia model WEBER ENERGY 4500.
Technical Data
WEBER ENERGY (2500) | WEBER ENERGY (4500) | WEBER ENERGY (6500) | WEBER ENERGY (8500) | |
Rated power of the unit AC [W] | 2000 | 2700 | 5000 | 7000 |
Maximum power of the unit AC [W] | 2200 | 3000 | 5500 | 7500 |
Nominal frequency of the unit AC [Hz] | 50 | 50 | 50 | 50 |
Rated voltage of the unit AC [V] | 230 | 230 | 230/400 | 230/400 |
Rated current AC [A] | 8.7 | 11.8 | 9.1 | 12.7 |
Rated current DC [A] | 8.3 | |||
Nominal voltage DC [V] | 12 | |||
voltage regulation | AVR | |||
number of phases | 1 | 1 | 3 | 3 |
Number and type of sockets [pieces x V] | 2x230 | 2x230 | 2x230/1x400 | 2x230/1x400 |
insulation class | F | |||
protection class | IP23M | |||
Rated engine power/speed [KM/rpm] | 7/3600 | 7/3600 | 13/3600 | 18/3600 |
engine model | JP170 | JP170 | JP188 | JP192 |
engine type | 4-stroke, 1 cylinder, air-cooled | |||
engine displacement [cc] | 208 | 208 | 389 | 458 |
Diameter x Motor Stroke [mm] | 70x54 | 70x54 | 88x64 | 88x64 |
power factor | 1 | 1 | 0.8 | 0.8 |
performance class | G1 | G1 | G1 | G1 |
protection class | IP23M | IP23M | IP23M | IP23M |
ignition system | TCI | TCI | TCI | TCI |
start-up | manually | |||
fuel type | unleaded gasoline | |||
fuel tank capacity | 15 | 15 | 25 | 25 |
Maximum duration of continuous operation | 12 | 12 | 10 | 8 |
oil type | SAE10W/30 | |||
capacity of the oil tank | 0.6 | 0.6 | 1.1 | 1.1 |
Sound power level 7m [dB (A)] | 95 | 95 | 99 | 99 |
sound pressure level dB(A) | 76 | 76 | 79 | 79 |
Weight [kg] | 42 | 46 | 89 | 89 |
Dimensions [mm] | 627×476×479 | 715×573×570 | ||
Maximum operating temperature - air [°C] | 40 |